Description
Product Details
CU-3E19RBU-5
Panasonic multizone 3 Zone (Triple Zone) 19000 BTU/h outdoor condenser unit provides heating and cooling for up to 3 indoor units and -21°C (-5°F) cold climate heat operation. Select wall mount, 4-way cassette or slim duct units for indoor installation alongside the air conditioner condenser.
nanoe™ X ClimaPure™ Compatibility
Panasonic ClimaPure™ XE indoor units come with built-in WiFi connectivity, air and surface purification technology that provides a comfortable environment for occupants by reducing pollutants and odours.
Key Features
- Cooling Capacity: 19,000 (6,100 – 24,800) Btu/h
- Heating Capacity: 26,000 (5,000 – 28,400) Btu/h
- SEER Non-Ducted 22.0 / Ducted 18.5
- SEER Non-Ducted 12.55 / Ducted 10.85;
- HSPF Non-Ducted 10.5 / Ducted 9.0
- Blue Fin Condenser with anti-rust coating
- ENERGY STAR® rated (Non-Ducted)
- Eligible product for the Canada Greener Homes Grant (Non-Ducted)
- nanoe™ X ClimaPure™ Compatibility
- Optional and Built-in WiFi connectivity (depends on the indoor units)
Compatibile indoor units
Wall Mounted | 4-Way Ceiling Cassette | Low-Profile Ducted |
---|---|---|
CS-ME5RKUA | — | CS-ME5SD3UA |
CS-ME7RKUA | — | CS-ME7SD3UA |
CS-E9RKUAW, CS-XE9WKUAW | CS-ME9SB4U | CS-E9SD3UAW |
CS-E12RKUAW, CS-XE12WKUAW | CS-E12RB4UW | CS-E12SD3UAW |
CS-XE15WKUAW | — | — |
CS-E18RKUAW, CS-XE18WKUAW | CS-E18RB4UW | CS-E18SD3UAW |
A system sizing calculation for multizone ductless air conditioners that plans for diversity may size up to approximately 130% of indoor unit demand versus the outdoor unit’s system capacity provided that planned operating demand throughout the day never exceeds 100% of system capacity. If there is no planned Diversity then the indoor unit demand should not exceed 100% of the outdoor unit capacity.
Therefore, a first step in sizing and selecting any multizone system is to understand the System Demand that the building requires before moving on to selecting Indoor unit combinations.
Combination Chart
2 Zones | 3 Zones | |
---|---|---|
5 + 12 | 5 + 5 + 5 | 7 + 7 + 7 |
5 + 15 | 5 + 5 + 7 | 7 + 7 + 9 |
5 + 18 | 5 + 5 + 9 | 7 + 7 + 12 |
7 + 9 | 5 + 5 + 12 | 7 + 7 + 15 |
7 + 12 | 5 + 5 + 15 | 7 + 7 + 18 |
7 + 15 | 5 + 5 + 18 | 7 + 9 + 9 |
7 + 18 | 5 + 7 + 7 | 7 + 9 + 12 |
9 + 9 | 5 + 7 + 9 | 7 + 9 + 15 |
9 + 12 | 5 + 7 + 12 | 7 + 12 + 12 |
9 + 15 | 5 + 7 + 15 | 9 + 9 + 9 |
9 + 18 | 5 + 7 + 18 | 9 + 9 + 12 |
12 + 12 | 5 + 9 + 9 | 9 + 9 + 15 |
12 + 15 | 5 + 9 + 12 | 9 + 12 + 12 |
12 + 18 | 5 + 9 + 15 | — |
15 + 15 | 5 + 12 + 12 | — |
15 + 18 | 5 + 12 + 15 | — |
The Panasonic Zoned Heating System is Eligible for The Canada Greener Homes Grant
Outdoor Unit | Indoor Unit | Grant Amount |
---|---|---|
CU-3E19RBU-5 | 3 non-ducted IDUs | $5000 |
CU-3E19RBU-5 | 2 non-ducted IDUs | $2500 |
Product Specifications
Capacity Cooling (BTU/H) | 19,000 (6,000 – 24,000) |
---|---|
Capacity Heating (BTU/H) | 26,000 (5,000 – 28,400) |
SEER – Cooling | Non-Ducted 22.0 / Ducted 18.5 |
EER – Cooling | Non-Ducted 12.55 / Ducted 10.85 |
HSPF – Heating | Non-Ducted 10.5 / Ducted 9.0 |
Power Supply (V, Phase, Hz) | 208 ~ 230V, 1PH, 60Hz |
Running Amps – Cooling (A) | Non-Ducted 7.4-6.7 / Ducted 8.5-7.7 |
Running Amps – Heating (A) | Non-Ducted 10.1-9.1 / Ducted 12.3-11.1 |
Power Input – Cooling (W) | 1,510 (360-2,420) |
Power Input – Heating (W) | 2,060 (320-2,300) |
Controls | Microprocessor |
Fan Speeds | Variable Speed |
Compressor | Twin Rotary, DC Motor, Inverter |
Refrigerant | R-410A / 93.2 oz. |
Refrigerant Control | Electric Expansion Valve |
Operation Sound – Outdoor (Hi) (dB-A) Cooling | 50 |
Operation Sound – Outdoor (Hi) (dB-A) Heating | 52 |
Refrigerant Tubing Connections | Flare |
Max. Allowable Tubing Length (ft) | 164 per system (82 per indoor unit) |
Refrigerant Tube Diameter – Discharge (IN) | 1/4″ × 3 |
Refrigerant Tube Diameter – Suction (IN) | 3/8″ × 3 |
Adapter Required | Indoor 12 and 18 Btu/hr. require 1 CZ-MA1P-US |
Dimensions (H × W × D) | 31 5⁄16″ × 34 15⁄32″ × 14 3⁄16″ |
Net Weight (LBS) | 159 |